3400.41.0203
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | No DC / shorted QW or LC |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 5 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | Quarter-wave stub technology |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | 0.1 dB |
Product code | 3400.41.0203 |
Main path connectors | Port 1: unprotected, 7/16 plug (male)Port 2: protected, 7/16 jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | IP67 |
Frequency frame | 380 MHz to 512 MHz |
Mounting and grounding | MH74 (bulkhead mounting), M8 (screw), brk (bracket) |
Return loss typical | 20 dB |
Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Silver PlatingPort 2: Copper Beryllium Alloy / Silver Plating |
EMP can be install reversed | YES |
PIM 3rd order | -150 dBc typ. |
Mating cycles | 500 |
CW power frame | 3000 W |
Weight | 580 g |