3403.17.0050 Lynvern Fine Protector m/gas capsule
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | Yes DC, GDT included, replaceable, 9071.99.0548 (90 V) |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 6 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | Fine protector hybrid technology |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
DC supply voltage | 15 V |
Insertion loss typical | ≤ 0.5 dB |
Product code | 3403.17.0050 |
Main path connectors | Port 1: unprotected, N jack (female)Port 2: protected, N jack (female) |
Housing material / plating | Aluminium / Chromatized |
Ingress protection (IP Rating) | Mated / IP65, according to IEC 60529 |
Frequency frame | 650 MHz to 2500 MHz |
Mounting and grounding | MH119 (bulkhead mounting), M4 (screw) |
Residual pulse voltage (typ.) | 18 V LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Return loss typical | ≥ 20.8 dB |
Surge current handling capability | 30 kA single, 20 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
DC current | 3 A |
Mating cycles | 500 |
CW power frame | ≤ 50 W |
Weight | 330 g |