ENVIROFLEX_178
Radiation Test | IEC 60068-2-5, proc. C |
Installation Temperature max. | 60°C |
Operating Temperature min. | -40°C |
Attenuation Coefficient b max. | 0.2452 |
Attenuation Coefficient b | 0.2229 |
Attenuation Coefficient a | 1.4067 |
Attenuation Coefficient a max. | 1.5474 |
Calculated Power | false |
Centre Conductor Diameter | 0.305mm |
Centre Conductor Material | Steel, Copper+Silver plated |
Conductor Inner Diameter | 0.102mm |
Inner Cond Res DC | 747Ohm/km, 802.2Ohm/km |
Installation Temperature min. | -20°C |
Operating Temperature max. | 105°C |
Outer Conductor 2 Description | Outer conductor |
Outer Conductor 3 Description | Outer conductor |
Outer Conductor 4 Description | Outer conductor |
Screen Frequency max. | 3GHz |
Screen Frequency min. | 0.03GHz |
Outer Cond Resistance DC | 50Ohm/km, 55Ohm/km |
Outer Cond1 Coverage | 95% |
Outer Conductor1 Diameter | 1.27mm |
Outer Conductor1 Material | Copper, Silver plated |
Phase vs Temperature Ratio | 8400ppm |
Class | 1148 |
2006/1907/EC (REACH) | compliant |
Ageing Test | MIL-C-17 § 4.8.16 |
Alternative Cable | RG_178_B/U |
Armoring 1 Description | Armor |
Armoring 2 Description | Armor |
Armoring 3 Description | Armor |
Armoring 4 Description | Armor |
Bending Force Moment | 0.02Nm |
Bending Frequency | 1GHz |
Bending Radius | 20mm |
Bending Test Procedure | 360 |
Cable Category | Flexible RF cable |
Cable Family | Enviroflex: LSFH alternatives to RG cables |
Kabelgruppe - Kabel | U1 |
Calc IL/Power up to Freq | 17MHz |
Capacitance | 94.5pF/m |
Centre Conductor Design | Strand-07 |
Cold Bend Test | MIL-C-17 § 4.8.19 |
CW Power | 60W |
CW Power Frequency | 1GHz |
Description | RG178 LSFH, 50 Ohm, 3 GHz, 105°C, ø1.84 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter | 0.82mm |
Dielectric Material | SPEX (Crosslink Foam PE) |
Distribution txt | RG178 LSFH, 50 Ohm, 3 GHz, 105°C, ø1.84 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dynamic Bend Radius | 30mm |
Fire Test a | UL 1581 § 1100 |
Halogen Free | true |
Halogen Test | IEC 60754 |
ID | ENVIROFLEX_178 |
Impedance | 50Ohm |
Impedance Tolerance ± | 2Ohm |
Insulation Resistance | 10000000MOhm/m |
Jacket Colour | RAL 5010 - bl |
Jacket Diameter | 1.84mm |
Jacket Material | RADOX |
Jacket Tolerance | 0.07mm |
2011/65/EC (RoHS) | compliant |
Number of Cycles | 30000 |
Number of Screens | 1 |
Only as Assembly | false |
Operating Frequency | 3GHz |
Operating Voltage | 1kV |
Outer Conductor1 Design | Braid |
Phase Temperature max. | 100°C |
Phase Temperature min. | -40°C |
Phase vs. Bending | 0.7°/GHz |
Print on Jacket | HUBER+SUHNER ENVIROFLEX 178 50 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity | 70.7% of c |
Repeated Bend Radius | 20mm |
Weight | 0.65kg/100m |
Screen Effectiveness | 40dB |
Signal Delay | 4.71ns/m |
Specification Voltage | 300kV |
Static Bend Radius | 5mm |
Temperature Rating UL | 105°C |
Test Voltage | 2kV |
UV Resistance Test | IEC 60068-2-5, proc. C |
OBJECT_ID | 7516087 |