EF 179
Radiation Test | IEC 60068-2-5, proc. C |
Installation Temperature max. | 60 °C |
Operating Temperature min. | -40 °C |
Attenuation Coefficient b max. | 0.0798 |
Attenuation Coefficient b | 0.0725 |
Attenuation Coefficient a | 0.8288 |
Attenuation Coefficient a max. | 0.9117 |
Calculated Power | N |
Centre Conductor Diameter | 0.305 mm |
Centre Conductor Material | Steel, Copper+Silver plated |
Conductor Inner Diameter | 0.102 mm |
Inner Cond Res DC | 747 Ohm/km, 802.2 Ohm/km |
Installation Temperature min. | -20 °C |
Operating Temperature max. | 105 °C |
Outer Conductor 2 Description | Outer conductor |
Outer Conductor 3 Description | Outer conductor |
Outer Conductor 4 Description | Outer conductor |
Screen Frequency max. | 1 GHz |
Screen Frequency min. | 0.01 GHz |
Outer Cond Resistance DC | 37 Ohm/km, 43 Ohm/km |
Outer Cond1 Coverage | 94 % |
Outer Conductor1 Diameter | 2 mm |
Outer Conductor1 Material | Copper, Silver plated |
Phase vs Temperature Ratio | 8400 ppm |
2002/96/EC (WEEE) | no special marking needed |
Class | 1148 |
2006/1907/EC (REACH) | compliant |
2000/53/EC (ELV) | compliant |
Ageing Test | MIL-C-17 § 4.8.16 |
Alternative Cable | RADOX_RF_179 |
Armoring 1 Description | Armor |
Armoring 2 Description | Armor |
Armoring 3 Description | Armor |
Armoring 4 Description | Armor |
Bending Force Moment | 0.02 Nm |
Bending Frequency | 1 GHz |
Bending Radius | 20 mm |
Bending Test Procedure | 360 |
Cable Category | Flexible RF cable |
Cable Family | Enviroflex: LSFH alternatives to RG cables |
Kabelgruppe - Kabel | U5 |
Calc IL/Power up to Freq | 17 MHz |
Capacitance | 63 pF/m |
Centre Conductor Design | Strand-07 |
Cold Bend Test | MIL-C-17 § 4.8.19 |
CW Power | 45 W |
CW Power Frequency | 1 GHz |
Description | RG179 LSFH, 75 Ohm, 3 GHz, 105°C, ø2.54 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter | 1.55 mm |
Dielectric Material | SPEX (Crosslink Foam PE) |
Distribution txt | RG179 LSFH, 75 Ohm, 3 GHz, 105°C, ø2.54 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Fire Test a | UL 1581 § 1100 |
Fire Test b | IEC 60332-2 |
Fire Test c | EN 60332-1-2 |
Halogen Free | 1 |
Halogen Test | IEC 60754 |
ID | ENVIROFLEX_179 |
Impedance | 75 Ohm |
Impedance Tolerance ± | 3 Ohm |
Insulation Resistance | 10000000 MOhm/m |
Jacket Colour | RAL 5015 - bl |
Jacket Diameter | 2.54 mm |
Jacket Material | RADOX |
Jacket Tolerance | 0.07 mm |
2011/65/EC (RoHS) | compliant |
Number of Cycles | 50 |
Number of Screens | 1 |
Only as Assembly | N |
Operating Frequency | 3 GHz |
Operating Voltage | 1 kV |
Outer Conductor1 Design | Braid |
Phase Temperature max. | 100 °C |
Phase Temperature min. | -40 °C |
Phase vs. Bending | 0.7 °/GHz |
Print on Jacket | HUBER+SUHNER ENVIROFLEX 179 75 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity | 70 % of c |
Repeated Bend Radius | 25 mm |
Weight | 1.11 kg/100m |
Screen Effectiveness | 40 dB |
Signal Delay | 4.78 ns/m |
Smoke Test | EN 61034-2 |
Specification Voltage | 300 kV |
Static Bend Radius | 5 mm |
Temperature Rating UL | 105 °C |
Test Voltage | 2 kV |
UV Resistance Test | IEC 60068-2-5, proc. C |
OBJECT_ID | 7516089 |