|
Installation Temperature max. |
60°C |
Operating Temperature min. |
-40°C |
Attenuation Coefficient b max. |
0.1268 |
Attenuation Coefficient b |
0.1153 |
Attenuation Coefficient a |
0.1704 |
Torsion Frequency |
65GHz |
Attenuation Coefficient a max. |
0.1874 |
Calculated Power |
false |
Centre Conductor Diameter |
2.46mm |
Centre Conductor Material |
Copper, Silver plated |
Conductor Inner Diameter |
0.82mm |
Inner Cond Res DC |
4.75Ohm/km, 5Ohm/km |
Installation Temperature min. |
-20°C |
Operating Temperature max. |
105°C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
3GHz |
Screen Frequency min. |
0.001GHz |
Outer Cond Resistance DC |
4.845Ohm/km, 5.15Ohm/km |
Outer Cond1 Coverage |
92% |
Outer Conductor1 Diameter |
8mm |
Outer Conductor1 Material |
Copper, Silver plated |
Outer Cond2 Coverage |
99% |
Outer Conductor2 Diameter |
8.68mm |
Outer Conductor2 Material |
Copper, Silver plated |
Phase vs Temperature Ratio |
2800ppm |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
Abrasion Test |
MIL-T-81490 - §4.7.19 - prod. II - modified |
2000/53/EC (ELV) |
compliant |
Ageing Test |
MIL-C-17 § 4.8.16 |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Bending Force Moment |
1.28Nm |
Bending Frequency |
1GHz |
Bending Radius |
100mm |
Bending Test Procedure |
360 |
Cable Category |
Flexible RF cable |
Cable Family |
Enviroflex: LSFH alternatives to RG cables |
Kabelgruppe - Kabel |
U33 |
Calc IL/Power up to Freq |
17MHz |
Capacitance |
94.5pF/m |
Centre Conductor Design |
Strand-07 |
Cold Bend Test |
MIL-C-17 § 4.8.19 |
CW Power |
495W |
CW Power Frequency |
1GHz |
Description |
RG393 LSFH, 50 Ohm, 6 GHz, 105°C, ø10.05 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter |
7.25mm |
Dielectric Material |
SPEX (Crosslink Foam PE) |
Distribution txt |
RG393 LSFH, 50 Ohm, 6 GHz, 105°C, ø10.05 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Fire Test a |
IEC 60332-2 |
Fire Test b |
UL 1581 § 1080 (VW-1) |
Fire Test c |
EN 60332-1-2 |
Halogen Free |
true |
Halogen Test |
IEC 60754 |
ID |
ENVIROFLEX_393 |
Impedance |
50Ohm |
Impedance Tolerance ± |
2Ohm |
Insulation Resistance |
10000000MOhm/m |
Jacket Colour |
black/bl line |
Jacket Diameter |
10.05mm |
Jacket Material |
RADOX |
Jacket Tolerance |
0.15mm |
2011/65/EC (RoHS) |
compliant |
Number of Cycles |
10000 |
Number of Screens |
2 |
Only as Assembly |
false |
Operating Frequency |
6GHz |
Operating Voltage |
5kV |
Outer Conductor1 Design |
Braid |
Outer Conductor2 Design |
Braid |
Phase Temperature max. |
100°C |
Phase Temperature min. |
-40°C |
Phase vs. Bending |
1.6°/GHz |
Print on Jacket |
HUBER+SUHNER ENVIROFLEX 393 50 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity |
70.7% of c |
Repeated Bend Radius |
100mm |
Weight |
18kg/100m |
Screen Effectiveness |
78dB |
Signal Delay |
4.71ns/m |
Smoke Test |
EN 61034-2 |
Specification Voltage |
300kV |
Static Bend Radius |
30mm |
Temperature Rating UL |
105°C |
Test Voltage |
10kV |
Thermal Stress Test |
IEC 61196-1 § 10.9 |
UV Resistance Test |
IEC 60068-2-5, proc. C |
OBJECT_ID |
7516096 |