Installation Temperature max. |
60°C |
Operating Temperature min. |
-40°C |
Attenuation Coefficient b max. |
0.0088 |
Attenuation Coefficient b |
0.008 |
Attenuation Coefficient a |
0.1241 |
Fire Test e |
IEC 60332-3-25 |
Attenuation Coefficient a max. |
0.1365 |
Calculated Power |
true |
Centre Conductor Diameter |
2.74mm |
Centre Conductor Material |
Aluminium / Copper |
Inner Cond Res DC |
4.75Ohm/km |
Installation Temperature min. |
-20°C |
Operating Temperature max. |
85°C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
6GHz |
Outer Cond Resistance DC |
6.06Ohm/km |
Outer Cond1 Coverage |
100% |
Outer Conductor1 Diameter |
7.4mm |
Outer Conductor1 Material |
Aluminum / PES |
Outer Cond2 Coverage |
78% |
Outer Conductor2 Diameter |
8.15mm |
Outer Conductor2 Material |
Copper, Tin plated |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
2000/53/EC (ELV) |
compliant |
Alternative Cable |
SPUMA_400 |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Cable Category |
Flexible RF cable |
Cable Family |
Spuma: Flexible, low-loss RF cables (LMR* alternatives) |
Kabelgruppe - Kabel |
U30 |
Calc IL/Power up to Freq |
17MHz |
Capacitance |
78pF/m |
Centre Conductor Design |
Wire |
Cold Bend Test |
MIL-C-17 § 4.8.19 |
CW Power |
600W |
CW Power Frequency |
1GHz |
Description |
50 Ohm, 8 GHz, 85°C, ø10.25 mm, LSFH jacket, Flame retardant, Railway and CPR qualified |
Dielectric Diameter |
7.24mm |
Dielectric Material |
SPE (Foamed Polyethylene) |
Distribution txt |
LMR* alternative, 50 Ohm, 8 GHz, 85°C, ø10.25 mm, LSFH jacket, Flame retardant, Railway and CPR qualified |
Fire Test a |
UL 1581 § 1100 |
Fire Test b |
UL 1581 § 1080 (VW-1) |
Fire Test c |
EN 60332-1-2 |
Fire Test d |
EN 50266-2-5 |
Halogen Free |
true |
Halogen Test |
IEC 60754 |
ID |
SPUMA_400-FR-01 |
Impedance |
50Ohm |
Impedance Tolerance ± |
2Ohm |
Insulation Resistance |
1000000MOhm/m |
Jacket Colour |
RAL 9005 - bk |
Jacket Diameter |
10.25mm |
Jacket Material |
LSFH (modified polyethylene) |
Jacket Tolerance |
0.1mm |
2011/65/EC (RoHS) |
compliant |
Number of Screens |
2 |
Only as Assembly |
false |
Operating Frequency |
8GHz |
Operating Voltage |
1.6kV |
Outer Conductor1 Design |
longitudinal Foil |
Outer Conductor2 Design |
Braid |
Print on Jacket |
HUBER+SUHNER SPUMA 400-FR-01 50 Ohm Cca-s2,d2,a1 (production order number) |
Propagation Velocity |
85% of c |
Repeated Bend Radius |
100mm |
Weight |
11.5kg/100m |
Screen Effectiveness |
90dB |
Signal Delay |
3.9ns/m |
Smoke Test |
EN 61034-2 |
Static Bend Radius |
25mm |
Test Voltage |
3kV |
UV Resistance Test |
ISO 4892-2A |
OBJECT_ID |
8711481 |