|
Installation Temperature max. |
60°C |
Operating Temperature min. |
-40°C |
Attenuation Coefficient b max. |
0.1431 |
Attenuation Coefficient b |
0.1301 |
Attenuation Coefficient a |
0.7648 |
Attenuation Coefficient a max. |
0.8412 |
Calculated Power |
false |
Centre Conductor Diameter |
0.54mm |
Centre Conductor Material |
Steel, Copper+Silver plated |
Conductor Inner Diameter |
0.18mm |
Inner Cond Res DC |
222.3Ohm/km, 234Ohm/km |
Installation Temperature min. |
-20°C |
Operating Temperature max. |
105°C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
6GHz |
Screen Frequency min. |
1GHz |
Outer Cond Resistance DC |
16.5Ohm/km, 19Ohm/km |
Outer Cond1 Coverage |
96% |
Outer Conductor1 Diameter |
1.99mm |
Outer Conductor1 Material |
Copper, Silver plated |
Outer Cond2 Coverage |
90% |
Outer Conductor2 Diameter |
2.44mm |
Outer Conductor2 Material |
Copper, Silver plated |
Phase vs Temperature Ratio |
10000ppm |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
Abrasion Test |
MIL-T-81490 - §4.7.19 - prod. II - modified |
2000/53/EC (ELV) |
compliant |
Ageing Test |
MIL-C-17 § 4.8.16 |
Alternative Cable |
RADOX_RF_316_D |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Bending Force Moment |
0.055Nm |
Bending Frequency |
1GHz |
Bending Radius |
30mm |
Bending Test Procedure |
360 |
Cable Category |
Flexible RF cable |
Cable Family |
Enviroflex: LSFH alternatives to RG cables |
Kabelgruppe - Kabel |
U4 |
Calc IL/Power up to Freq |
17MHz |
Capacitance |
94.5pF/m |
Centre Conductor Design |
Strand-07 |
Cold Bend Test |
MIL-C-17 § 4.8.19 |
CW Power |
110W |
CW Power Frequency |
1GHz |
Description |
RG316D/RD316 LSFH, 50 Ohm, 6 GHz, 105°C, ø3.16 mm, RADOX® jacket, Flame retardant, UL AWM style 3651, CPR qualified |
Dielectric Diameter |
1.53mm |
Dielectric Material |
SPEX (Crosslink Foam PE) |
Distribution txt |
RG316D/RD316 LSFH, 50 Ohm, 6 GHz, 105°C, ø3.16 mm, RADOX® jacket, Flame retardant, UL AWM style 3651, CPR qualified |
Dynamic Bend Radius |
30mm |
Fire Test a |
EN 60332-1-2 |
Fire Test b |
UL 1581 § 1100 |
Fire Test c |
EN 50305, 9.1.2 |
Fire Test d |
FAR 25.869 |
Flex Life Test |
MIL-T-81490 - §4.7.15 - prod. II - modified |
Halogen Free |
true |
Halogen Test |
IEC 60754 |
ID |
ENVIROFLEX_316_D |
Impedance |
50Ohm |
Impedance Tolerance ± |
2Ohm |
Insulation Resistance |
10000000MOhm/m |
Jacket Colour |
black/bl line |
Jacket Diameter |
3.16mm |
Jacket Material |
RADOX |
Jacket Tolerance |
0.08mm |
2011/65/EC (RoHS) |
compliant |
Number of Cycles |
30000 |
Number of Screens |
2 |
Only as Assembly |
false |
Operating Frequency |
6GHz |
Operating Voltage |
1.3kV |
Outer Conductor1 Design |
Braid |
Outer Conductor2 Design |
Braid |
Phase Temperature max. |
100°C |
Phase Temperature min. |
-40°C |
Phase vs. Bending |
0.7°/GHz |
Print on Jacket |
HUBER+SUHNER ENVIROFLEX 316 D 50 Ohm (UL logo) AWM Style 3651 Dca-s1b,d1,a1 (production order number) |
Propagation Velocity |
70.1% of c |
Repeated Bend Radius |
30mm |
Weight |
2.1kg/100m |
Screen Effectiveness |
70dB |
Signal Delay |
4.72ns/m |
Smoke Test |
EN 61034-2 |
Specification Voltage |
300kV |
Static Bend Radius |
5mm |
Temperature Rating UL |
105°C |
Test Voltage |
3kV |
Thermal Stress Test |
IEC 61196-1 § 10.9 |
UV Resistance Test |
IEC 60068-2-5, proc. C |
OBJECT_ID |
7516093 |