EF 400-01 Black
Installation Temperature max. | 60 °C |
Operating Temperature min. | -40 °C |
Attenuation Coefficient b max. | 0.149 |
Attenuation Coefficient b | 0.142 |
Attenuation Coefficient a | 0.402 |
Attenuation Coefficient a max. | 0.422 |
Calculated Power | N |
Centre Conductor Diameter | 1 mm |
Centre Conductor Material | Copper, Silver plated |
Conductor Inner Diameter | 0.2 mm |
Inner Cond Res DC | 29.45 Ohm/km, 31 Ohm/km |
Installation Temperature min. | -20 °C |
Operating Temperature max. | 105 °C |
Outer Conductor 2 Description | Outer conductor |
Outer Conductor 3 Description | Outer conductor |
Outer Conductor 4 Description | Outer conductor |
Screen Frequency max. | 5 GHz |
Screen Frequency min. | 0.001 GHz |
Outer Cond Resistance DC | 7.6 Ohm/km, 8 Ohm/km |
Outer Cond1 Coverage | 96 % |
Outer Conductor1 Diameter | 3.61 mm |
Outer Conductor1 Material | Copper, Silver plated |
Outer Cond2 Coverage | 94 % |
Outer Conductor2 Diameter | 4.2 mm |
Outer Conductor2 Material | Copper, Silver plated |
Phase vs Temperature Ratio | 10000 ppm |
Class | 1148 |
2006/1907/EC (REACH) | compliant |
Abrasion Test | MIL-T-81490 - §4.7.19 - prod. II - modified |
Ageing Test | MIL-C-17 § 4.8.16 |
Armoring 1 Description | Armor |
Armoring 2 Description | Armor |
Armoring 3 Description | Armor |
Armoring 4 Description | Armor |
Bending Force Moment | 0.26 Nm |
Bending Frequency | 1 GHz |
Bending Radius | 40 mm |
Bending Test Procedure | 360 |
Cable Category | Flexible RF cable |
Cable Family | Enviroflex: LSFH alternatives to RG cables |
Kabelgruppe - Kabel | U11 |
Calc IL/Power up to Freq | 17 MHz |
Capacitance | 94 pF/m |
Centre Conductor Design | Strand-19 |
Cold Bend Test | MIL-C-17 § 4.8.19 |
CW Power | 225 W |
CW Power Frequency | 1 GHz |
Description | RG400 LSFH (black jacket), 50 Ohm, 6 GHz, 105°C, ø4.97 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter | 2.98 mm |
Dielectric Material | SPEX (Crosslink Foam PE) |
Distribution txt | RG400 LSFH (black jacket), 50 Ohm, 6 GHz, 105°C, ø4.97 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dynamic Bend Radius | 40 mm |
Fire Test a | IEC 60332-1 |
Fire Test b | UL 1581 § 1100 |
Fire Test c | IEC 60332-2 |
Halogen Free | 1 |
Halogen Test | IEC 60754 |
ID | ENVIROFLEX_400-01 |
Impedance | 50 Ohm |
Impedance Tolerance ± | 2 Ohm |
Insulation Resistance | 10000000 MOhm/m |
Jacket Colour | RAL 9005 - bk |
Jacket Diameter | 4.97 mm |
Jacket Material | RADOX |
Jacket Tolerance | 0.1 mm |
2011/65/EC (RoHS) | compliant |
Number of Cycles | 30000 |
Number of Screens | 2 |
Only as Assembly | N |
Operating Frequency | 6 GHz |
Operating Voltage | 2.5 kV |
Outer Conductor1 Design | Braid |
Outer Conductor2 Design | Braid |
Phase Temperature max. | 100 °C |
Phase Temperature min. | -40 °C |
Phase vs. Bending | 0.5 °/GHz |
Print on Jacket | HUBER+SUHNER ENVIROFLEX 400-01 50 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity | 70.3 % of c |
Repeated Bend Radius | 40 mm |
Weight | 6 kg/100m |
Screen Effectiveness | 70 dB |
Signal Delay | 4.74 ns/m |
Smoke Test | DIN EN 50268-2 |
Specification Voltage | 300 kV |
Static Bend Radius | 10 mm |
Temperature Rating UL | 105 °C |
Test Voltage | 5 kV |
Thermal Stress Test | IEC 61196-1 § 10.9 |
UV Resistance Test | IEC 60068-2-5, proc. C |
OBJECT_ID | 7516098 |